Replace Your B452 with Confidence
Now that your B452 is at the end of its lifecycle...
Replacing it is made easy working with Reliance.
ULTRA 1212 LE VS. BRANSON B452
See how the ULTRA 2012 LE stacks up against the B452
| FEATURE | ULTRA™ 1212 LE | B452R |
|---|---|---|
| Ultrasonic Liquid Immersion Sump | 12"L x 12"W x 10"D | 12"L x 10"W x 8.5"D |
| Vapor Zone | 24"L x 12"W x 10"D | 24"L x 10"W x 8.5"D |
| Ultrasonic Configuration | Submersible and field replaceable | Adhered to bottom of tank (not field replaceable) |
| Ultrasonic Immersion Filtration | Yes, adjustable | Yes, limited |
| Freeboard Ratio | 120% Freeboard | 120% Freeboard |
| Sump Access Door | Doors on boil and immersion sump | None - cleanout over top of tank |
| Safety Limit Controls | Displays actual temperature and set point | No temperature display |
| Operator Lock-Out | Yes | No |
| Low Temperature Refrigeration Coils | Stainless Steel Continuous Coil - will not rust or leak | Coated Copper with elbows that leak |
| Spray Wand System | Yes, high capacity | Yes, limited capacity |
| Automated Basket Handling System | Yes, Sophisticated, Programmable | Yes, Limited, Manual |
| Control Panel | Comprehensive Indicator Light System | Limited Indicators |
| Heat | Electric: Replaceable, Screw In | Electric: Permanently Mounted |
| Solvent Compatibility | Yes, including new fluorinated | Limited for low-boil point solvents |
WHY ULTRA
ULTRA™ State-of-the-Art Ultrasonic Vapor Degreasers with Automation – provide highly reliable and effective cleaning capability that is an exceptional upgrade to the B452.
Expert Vapor Degreasing Support Staff – to seamlessly transition you from the B452 to ULTRA™ operation.
Field Maintenance Ease - Simple to change and replace key components, such as heating elements, ultrasonic generators and filters reduce maintenance down-time.
Solvent Compatibility - New low-boil point solvents require an upgrade from the B452 to a modern unit like the ULTRA™.
Complete Turn-Key Cleaning Solutions – we provide everything you need including solvent to upgrade your B452 vapor degreaser.
NESHAP COMPLIANT - The ULTRA™ System has a Freeboard Ratio > 120% and conforms to the feature requirements of NESHAP for easy change over from B452.
Exceptional Solvent Containment - Upgrade from the B452 to a Primary and Low Temperature Refrigerated Condensing System with Stainless steel coil and Copeland refrigeration system using standard refrigerant.