ULTRA 2012-LE FEATURES

  • NESHAP Compliant Vapor Degreasing System

  • Solid Stainless Steel Construction - Heavy gauge 304 stainless steel used on tank, water separator, spray reserve tank, primary coil, low-temperature coil, lid system, tank access doors and tank fittings.

  • Stainless Steel Primary Condensing Coil - New Copeland refrigeration system operating with standard R134A refrigerant.

  • Sub-Zero Temperature Condensing Coil - Finned stainless steel condensation coil with Copeland R404A refrigeration operating to approximately -20F thus broadening the height of the solvent flash-off dwell zone for enhanced solvent containment.

  • Foot Operated Spray Lance System - Mag-drive pump with distillate spray reservoir with Vapor Up Safety Control which requires presence of vapor to permit operation of spray wand.

  • High Volume Condensate Water Separator - feeding spray reservoir

  • Digital Display Safety Control Panel - including HTC, LTC, SVC, VU, RT

  • Ultrasonic Power – 500 Watts @ 40 kHz - field replaceable submersible transducers and plug in external ultrasonic generator for easy servicing

  • Ultrasonic Power - Input adjustment and sweep frequency adjustment

  • Ultrasonic Immersion Sump filtration and re-circulation system with mag-drive pump

  • WATLOW Temperature Safety Limit Controls - Digital display on control panel; temperature set point as well as actual temperature – SVC (Safety Vapor Control), HTC (High Temperature Control), LTC (Liquid Temperature Control) and RT (Refrigeration Temperature Control)

  • Low-Level Float Safety System - Ensures the minimum amount of solvent in boil sump for proper system operation.

  • Comprehensive Indicator Light System on Control Panel - Includes solvent low level float fault indicator lights (for easy identification of operating fault conditions). “Spray Ready” indicator light and zero coil “Defrost” indicator light, illuminated on/off switches for easy identification of system condition “Heat”, “Filtration”, Main Power”, “Refrigeration” and “Low-Temp Refrigeration”.

  • Horizontal Slide Lid - for solvent containment. Optional power roll-top available.

  • Casters - for easy movement.

  • Simple In and Out Electric Immersion Heater - “Screw-In” type elements for easy replacement.

  • Two Sump Access Clean-Out Doors - Boil sump and immersion sump access for ease of maintenance through the clean-out door rather than over the tank top

  • One (1) stainless steel workbasket

  • Comprehensive 1-Year Manufacturer’s Warranty

  • ULTRA™ 2012 LE Operator’s Manual

Next
Next

BENEFITS